10 research outputs found

    An externally validated fully automated deep learning algorithm to classify COVID-19 and other pneumonias on chest computed tomography.

    Full text link
    peer reviewedPurpose: In this study, we propose an artificial intelligence (AI) framework based on three-dimensional convolutional neural networks to classify computed tomography (CT) scans of patients with coronavirus disease 2019 (COVID-19), influenza/community-acquired pneumonia (CAP), and no infection, after automatic segmentation of the lungs and lung abnormalities. Methods: The AI classification model is based on inflated three-dimensional Inception architecture and was trained and validated on retrospective data of CT images of 667 adult patients (no infection n=188, COVID-19 n=230, influenza/CAP n=249) and 210 adult patients (no infection n=70, COVID-19 n=70, influenza/CAP n=70), respectively. The model's performance was independently evaluated on an internal test set of 273 adult patients (no infection n=55, COVID-19 n= 94, influenza/CAP n=124) and an external validation set from a different centre (305 adult patients: COVID-19 n=169, no infection n=76, influenza/CAP n=60). Results: The model showed excellent performance in the external validation set with area under the curve of 0.90, 0.92 and 0.92 for COVID-19, influenza/CAP and no infection, respectively. The selection of the input slices based on automatic segmentation of the abnormalities in the lung reduces analysis time (56 s per scan) and computational burden of the model. The Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis (TRIPOD) score of the proposed model is 47% (15 out of 32 TRIPOD items). Conclusion: This AI solution provides rapid and accurate diagnosis in patients suspected of COVID-19 infection and influenza

    Distributed learning for optimal radiomics knowledge

    Get PDF
    This thesis evaluated the current state of research in the field of radiomics and presented an up-to-date overview of distributed learning applications in health care and their limitations. It also presented a new infrastructure to address the limitations of the existing distributed learning solution. The potential of decentralizing the learning process by enforcing trust, immutability, transparency, and traceability in distributed learning networks via blockchain smart contracts was studied. The results showed that the decentralization of distributed learning networks has the potential to train the models on patient data stored at different health care centres without need to exchange patient data or to trust a third party. Furthermore, it evaluated the potential of distributed learning on small sets of data that can mimic the case of low prevalence diseases and phase I clinical trials, where it is not possible for a single health care provider to hold enough data to train reliable AI models. The results suggest that distributed learning 1) overcomes data sharing limitations for low prevalence diseases and can be the new way to apply AI for such diseases, 2) is capable to train models as good as centrally trained models. Moreover, an infrastructure was deployed to a public blockchain (Ethereum) test network and tested the feasibility of decentralized distributed learning in real world settings. The decentralized nature of the study makes it easy for the public to evaluate the time, cost, and the learning quality, hence reaching transparent learning process

    A review of classical and fractional derivative order methods for edge detection in image processing

    No full text
    The main goal of this work is compare between the classical edge detectors and an approach of edge detection based on fractional differentiation. Classical edge detectors based on first order derivative: Prewitt, Sobel and Canny and one edge detector based on second order derivative: Laplacian is discussed. Also the 2nd order fractional differentiation approach of edge detection is presented. To check the effect of image smoothing on edge detection results additionally, for results comparison between different methods, a smoothing filter is applied for Prewitt, Sobel, Laplacian. The comparison is conducted from time consuming point of view and quality of edge detection level

    Systematic Review of Privacy-Preserving Distributed Machine Learning From Federated Databases in Health Care

    Get PDF
    Big data for health care is one of the potential solutions to deal with the numerous challenges of health care, such as rising cost, aging population, precision medicine, universal health coverage, and the increase of noncommunicable diseases. However, data centralization for big data raises privacy and regulatory concerns.Covered topics include (1) an introduction to privacy of patient data and distributed learning as a potential solution to preserving these data, a description of the legal context for patient data research, and a definition of machine/deep learning concepts; (2) a presentation of the adopted review protocol; (3) a presentation of the search results; and (4) a discussion of the findings, limitations of the review, and future perspectives.Distributed learning from federated databases makes data centralization unnecessary. Distributed algorithms iteratively analyze separate databases, essentially sharing research questions and answers between databases instead of sharing the data. In other words, one can learn from separate and isolated datasets without patient data ever leaving the individual clinical institutes.Distributed learning promises great potential to facilitate big data for medical application, in particular for international consortiums. Our purpose is to review the major implementations of distributed learning in health care

    Development and validation of an automated radiomic CT signature for detecting COVID-19

    Full text link
    peer reviewedThe coronavirus disease 2019 (COVID-19) outbreak has reached pandemic status. Drastic measures of social distancing are enforced in society and healthcare systems are being pushed to and beyond their limits. To help in the fight against this threat on human health, a fully automated AI framework was developed to extract radiomics features from volumetric chest computed tomography (CT) exams. The detection model was developed on a dataset of 1381 patients (181 COVID-19 patients plus 1200 non COVID control patients). A second, independent dataset of 197 RT-PCR confirmed COVID-19 patients and 500 control patients was used to assess the performance of the model. Diagnostic performance was assessed by the area under the receiver operating characteristic curve (AUC). The model had an AUC of 0.882 (95% CI: 0.851-0.913) in the independent test dataset (641 patients). The optimal decision threshold, considering the cost of false negatives twice as high as the cost of false positives, resulted in an accuracy of 85.18%, a sensitivity of 69.52%, a specificity of 91.63%, a negative predictive value (NPV) of 94.46% and a positive predictive value (PPV) of 59.44%. Benchmarked against RT-PCR confirmed cases of COVID-19, our AI framework can accurately differentiate COVID-19 from routine clinical conditions in a fully automated fashion. Thus, providing rapid accurate diagnosis in patients suspected of COVID-19 infection, facilitating the timely implementation of isolation procedures and early intervention

    Development and Validation of an Automated Radiomic CT Signature for Detecting COVID-19.

    Full text link
    peer reviewedThe coronavirus disease 2019 (COVID-19) outbreak has reached pandemic status. Drastic measures of social distancing are enforced in society and healthcare systems are being pushed to and beyond their limits. To help in the fight against this threat on human health, a fully automated AI framework was developed to extract radiomics features from volumetric chest computed tomography (CT) exams. The detection model was developed on a dataset of 1381 patients (181 COVID-19 patients plus 1200 non COVID control patients). A second, independent dataset of 197 RT-PCR confirmed COVID-19 patients and 500 control patients was used to assess the performance of the model. Diagnostic performance was assessed by the area under the receiver operating characteristic curve (AUC). The model had an AUC of 0.882 (95% CI: 0.851-0.913) in the independent test dataset (641 patients). The optimal decision threshold, considering the cost of false negatives twice as high as the cost of false positives, resulted in an accuracy of 85.18%, a sensitivity of 69.52%, a specificity of 91.63%, a negative predictive value (NPV) of 94.46% and a positive predictive value (PPV) of 59.44%. Benchmarked against RT-PCR confirmed cases of COVID-19, our AI framework can accurately differentiate COVID-19 from routine clinical conditions in a fully automated fashion. Thus, providing rapid accurate diagnosis in patients suspected of COVID-19 infection, facilitating the timely implementation of isolation procedures and early intervention

    Deep learning for the fully automated segmentation of the inner ear on MRI

    Get PDF
    Abstract Segmentation of anatomical structures is valuable in a variety of tasks, including 3D visualization, surgical planning, and quantitative image analysis. Manual segmentation is time-consuming and deals with intra and inter-observer variability. To develop a deep-learning approach for the fully automated segmentation of the inner ear in MRI, a 3D U-net was trained on 944 MRI scans with manually segmented inner ears as reference standard. The model was validated on an independent, multicentric dataset consisting of 177 MRI scans from three different centers. The model was also evaluated on a clinical validation set containing eight MRI scans with severe changes in the morphology of the labyrinth. The 3D U-net model showed precise Dice Similarity Coefficient scores (mean DSC-0.8790) with a high True Positive Rate (91.5%) and low False Discovery Rate and False Negative Rates (14.8% and 8.49% respectively) across images from three different centers. The model proved to perform well with a DSC of 0.8768 on the clinical validation dataset. The proposed auto-segmentation model is equivalent to human readers and is a reliable, consistent, and efficient method for inner ear segmentation, which can be used in a variety of clinical applications such as surgical planning and quantitative image analysis